Remote Gateway 9150 Installation and Administration Guide

53

January 2005

Planning for Remote Gateway 9150 unit installation

!

An RJ-45 connector (labeled ETHERNET) provides a 10BaseT Ethernet
connection. This connection provides the ability to pass both voice and data
administration traffic over the existing Ethernet network.

!

A DB-9 connector (labeled ADMIN) provides an RS-232 serial port
connection. You can use this serial port connection to configure a Remote
Gateway 9150 unit that is directly connected to a PC.

Cables included with the Remote Gateway 9150 unit

The Remote Gateway 9150 unit package includes the following cables:

!

power cord and power supply
Notes:
— In North America, the power cord and power supply are included inside

the Remote Gateway 9150 box. In all other regions, the power supply is
provided inside the box. However, the power cord for your region is
provided outside the box.

— When the North American power cord and power supply are connected

together, they are 3.2 meters (10.4 feet) in length.

— If you connect the Remote Gateway 9150 unit to an uninterruptible

power supply then the UPS must have a minimum of 100 Watts
available.

!

RS-232 serial cable
If the RS-232 cable is not long enough, you can supply your own cable, up
to 15.38 meters (50 feet) in length.

Cables you must supply yourself

The cables used to establish the telephone and Ethernet network connections are
industry-standard cables. They are not provided in the Remote Gateway 9150
package. You must obtain them from your local cable supplier.

Telephone network cables
The telephone network cables establish the telephone and trunk connections.

One end of the cable must provide a male 50-pin connector. (This end connects
to the Remote Gateway 9150 unit.)