Physical environment, Space – Nortel Networks 9150 User Manual
Page 80

50
Remote Gateway 9150 Installation and Administration Guide
Planning for Remote Gateway 9150 unit installation
Standard 3.1
Physical environment
This section provides the space, temperature, cabling, and mounting information
you need to know before you install the Remote Gateway 9150 unit.
Space
Ensure that the Remote Gateway 9150 unit is installed in a location that is dry
and provides plenty of air circulation.
The chosen location must be no more than cable-length distance from the
following:
!
the administration PC (if the serial connection is used)
!
the Ethernet hub
!
trunk and telephone connection interfaces
The Remote Gateway 9150 unit can be installed up to
!
1230.7 meters (4000 feet) from the digital telephones
!
307.7 meters (1000 feet) from the analog device
It is recommended that you install the Remote Gateway 9150 unit in the same
room where your communications equipment is installed.