Installing the remote gateway 9150 unit, Choosing a suitable location – Nortel Networks 9150 User Manual

Page 128

Advertising
background image

98

Remote Gateway 9150 Installation and Administration Guide

Installing the Remote Gateway 9150 unit

Standard 3.1

Installing the Remote Gateway 9150 unit

You can install the Remote Gateway 9150 unit in the following locations:

!

on a desk (refer to page 99)

!

on a wall (refer to page 100)

!

in a rack (refer to page 103)

The Remote Gateway 9150 unit package contains the following hardware:

!

rubber feet for installing the Remote Gateway 9150 unit on a desk

!

brackets with screws for installing the Remote Gateway 9150 unit in a rack

Note: If you want to mount the Remote Gateway 9150 unit on a wall, you must
provide your own mounting hardware.

Choosing a suitable location

The Remote Gateway 9150 unit dimensions are:

!

42.5 cm (17 in.) wide (without rack-mounting brackets)

!

29.4 cm (11.75 in.) deep

!

4.4 cm (1.75 in.) high

For guidelines on where to install the Remote Gateway 9150 unit, refer to
“Physical environment” on page 50.

Note: Nortel recommends that you install the Remote Gateway 9150 unit in the
same room as your communications equipment. Locate the Remote Gateway
9150 unit no farther than:

!

1230.7 m (4000 ft) from the digital telephones

!

307.7 m (1000 ft) from the analog device