Nortel Networks 9150 User Manual

Page 505

Advertising
background image

Remote Gateway 9150 Installation and Administration Guide

475

January 2005 Display

log

definitions

Statistic

Definition

LOG NUMBER

87

DESCRIPTION

This log indicates that a DSP has been taken Out Of Service. This
can occur for the following reasons:
1) Download or initialization failure (such as, at system startup)
2) Dynamic DSP failure with automatic recovery
3) User execution of the DSP restart debug command, which first

takes the DSP OOS, then tries to restart it

SEVERITY

MAJOR (CRITICAL on 911x)

TASK

VPM

PRODUCT

RLC, 9150, 911x

CANCELLATION

This action is followed by either log number 83 or 84, to indicate
reload SUCCESS or FAILURE, respectively.

ACTION TO BE TAKEN

No action is required unless this results from DSP load failure (refer
to log number 84).

PARAMETERS

1) Single-digit DSP device ID
2) DSP module number
3) DSP device number

DISPLAYED TEXT

DSP #P1 taken OOS. (Module, Device) = (P2, P3)

PRODUCES HOST PBX
ALARM AND ALERT

Yes

Advertising