Nortel Networks 9150 User Manual
Page 505

Remote Gateway 9150 Installation and Administration Guide
475
January 2005 Display
log
definitions
Statistic
Definition
LOG NUMBER
87
DESCRIPTION
This log indicates that a DSP has been taken Out Of Service. This
can occur for the following reasons:
1) Download or initialization failure (such as, at system startup)
2) Dynamic DSP failure with automatic recovery
3) User execution of the DSP restart debug command, which first
takes the DSP OOS, then tries to restart it
SEVERITY
MAJOR (CRITICAL on 911x)
TASK
VPM
PRODUCT
RLC, 9150, 911x
CANCELLATION
This action is followed by either log number 83 or 84, to indicate
reload SUCCESS or FAILURE, respectively.
ACTION TO BE TAKEN
No action is required unless this results from DSP load failure (refer
to log number 84).
PARAMETERS
1) Single-digit DSP device ID
2) DSP module number
3) DSP device number
DISPLAYED TEXT
DSP #P1 taken OOS. (Module, Device) = (P2, P3)
PRODUCES HOST PBX
ALARM AND ALERT
Yes