Remote Gateway 9150 Installation and Administration Guide

Installing the Remote Gateway 9150 unit

Standard 3.1

6

Connect the ADMIN connector on the Remote Gateway 9150 unit to the
administration PC as follows:

a. Connect the male 9-pin connector of the supplied RS-232 serial cable

to the ADMIN connector on the Remote Gateway 9150 unit.

Note: You may need to provide an RS-232 adapter if the available
RS-232 port on your PC does not match the connector on the serial
cable.

b. Connect the other end to an available COM port on the PC.

7

Connect the Remote Gateway 9150 unit to the power source as follows:

a. Connect the four-pin plug on the power transformer to the POWER

connector on the Remote Gateway 9150 unit.

Note: Ensure the arrow on the four-pin plug faces up.

b. Connect the AC cord to the AC power receptacle on the power

transformer.

c. Plug the AC cord into a 110 V or 220 V uninterruptible power source

(UPS) or wall outlet.

8

Proceed with “Powering up the Remote Gateway 9150 unit” on page 111.