Configuring the Remote Gateway 9150 unit

ATA- and MCA-equipped stations and bandwidth requirements

Each station equipped with an MCA requires a full 64 Kbps of bandwidth to the
host PBX.

For stations equipped with ATA devices, the bandwidth used by calls processed
on those stations is as follows:

The following table identifies the number of MCAs or ATAs that can be
connected to the Remote Gateway 9150 unit:

Notes:

!

You can have eight MCAs or ATAs installed if an analog telephone or fax
machine is not installed.

!

You can have up to 32 digital telephone sets, one fax machine, and seven
ATA/MCAs installed. However, only 32 simultaneous calls can be made.

IF using

THEN

G.729A compression and the call
is a voice call,

the voice call is sent as 8 Kbps to the
host PBX.

G.729A/Fax compression and the
call is a fax call,

the fax call is sent as 9600 bps.

G.711 compression
(uncompressed) and the call is a
fax call

the fax call is sent as 64 Kbps.

the call is a local call,

the voice call is not compressed. It is
sent as 64 Kbps of data across the
ISDN BRI B-channel.

IF the Remote Gateway 9150 unit

is connected to

THEN you can connect

a 1-slot RLC
(supporting 16 users),

four MCAs or ATAs to the Remote
Gateway 9150 unit.

a 2-slot RLC
(supporting 32 users),

seven MCAs or ATAs to the Remote
Gateway 9150 unit.