Install and configure IP Trunk 3.01 (and later) node

CAUTION

Equipment Damage

Do not overtighten screws. They can break.

Follow the steps in

Procedure 7 "Installing and cabling the ITG-Pentium

24-port trunk card" (page 192)

on

Procedure 7 "Installing and cabling

the ITG-Pentium 24-port trunk card" (page 192)

to install and cable the

ITG-Pentium 24-port trunk card.

Procedure 7

Installing and cabling the ITG-Pentium 24-port trunk card

Step

Action

1

Identify the IPE card slots selected for the IP trunk card(s). Use the
recorded information from the IP Trunk 3.01 (and later) Installation
Summary Sheet (

Table 38 "IP Trunk 3.01 (and later) Installation

Summary Sheet" (page 184)

).

2

Remove any existing I/O panel cables associated with any card
previously installed in the selected card slot.

3

Install the NTWE07AA DCHIP PC Card into the internal PC Card slot
on the IP trunk card that has been selected to provide the DCHIP
function. (See

Figure 34 "DCHIP PC Card and NTCW84EA pigtail

cable" (page 193)

on

Figure 34 "DCHIP PC Card and NTCW84EA

pigtail cable" (page 193)

.)

4

Connect the NTCW84EA pigtail cable from port 0 of the DCHIP PC
Card to the J14 pin header on the motherboard of the DCHIP card.
See

Figure 34 "DCHIP PC Card and NTCW84EA pigtail cable"

(page 193)

.

The cable routes the D-Channel signals to the backplane and the I/O
panel. The PC Card connector is keyed to allow insertion only in the
correct direction. The J-14 pin header connector is not keyed. Be
careful to align the connector with the pin header.