Install and configure IP Trunk 3.01 (and later) node

For more detailed cabling information and procedures for replacing the
NT8D81BA with the NT8D81AA, see

Appendix "Patches and advisements"

(page 429)

.

Install NTMF94EA and NTCW84KA cables

The Media Card 32-port and ITG-Pentium 24-port trunk card supports a
one-cable solution for access to the TLAN network interface, ELAN network
interface, and serial ports. The ELAN network interface supports 10BaseT
operation and the TLAN network interface supports 10/100BaseT operation.
If using a 100BaseT operation on the TLAN network interface, install a
NTCW84JA 50-pin I/O panel filter connector block to replace the standard
I/O connectors provided.

Cables that are provided for the ELAN and TLAN network interface functions
include the following:

the NTMF94EA ELAN, TLAN, and RS-232-port cable (for non-DCHIP
cards)

the NTCW84KA ELAN, TLAN, RS-232 and DCH Ports cable (for DCHIP
cards)

Install the NTCW84KA cable (for DCHIP cards)

Follow the steps in

Procedure 9 "Installing the NTCW84KA cable" (page

196)

to connect the NTCW84KA cable for DCHIP cards.

Procedure 9

Installing the NTCW84KA cable

Step

Action

1

Connect the NTCW84KA cable see to the I/O panel connector (see

Figure 36 "NTCW84KA ELAN, TLAN, DCH, and serial cable" (page
197)

).

Make sure to connect to the I/O panel connector that corresponds to
the left slot number of the DCHIP card.

2

Secure the mounting screw provided on the top of the Shielded
25-Pair Amphenol Connector to the I/O Panel filter connector in
order to tie the shield of the LAN cable to the frame ground for EMC
compliance.

—End—

Nortel Communication Server 1000

IP Trunk Fundamentals

NN43001-563

01.01

Standard

Release 5.0

30 May 2007