Install and configure IP Trunk 3.01 (and later) node

NTAG81BA Maintenance Extender cable to provide an extension
between the NTAG81CA PC Maintenance cable and the TM 3.1 PC.

Alternatively, connect the NTAG81BA Maintenance Extender
cable to the female DB-9 connector of the NTCW84KA
Management Port, DCH, and Serial I/O cable for DCHIP
cards, or the NTMF94EA ELAN, TLAN, RS-232-ports cable for
non-DCHIP cards, to create a more permanent connection to the
IP trunk card serial maintenance port.

Never connect two terminals to the faceplate and I/O panel breakout
cable serial maintenance port connectors at the same time.

2

Use the following communication parameters for the TTY terminal
emulation on the TM 3.1 PC:

9600 baud

8 bits

no parity bit

1 stop bit

When a new IP trunk card starts up and displays "T:20" on the
4-character display, the IP trunk card begins sending BOOTP
requests on the ELAN subnet. A series of dots appears on the TTY.

3

Type

+++

to bring up the ITG shell CLI prompt:

...+++

When prompted to login, enter the default username and password
as:

VxWorks login:

itgadmin

Password:

itgadmin

ITG>

4

When the ITG shell prompt appears on the TTY, enter the IP address
for the Leader card:

Wait until the display shows "T:21," then enter:
ITG>

setLeader "xxx.xxx.xxx.xxx",

"yyy.yyy.yyy.yyy","zzz.zzz.zzz.zzz"

where

"xxx.xxx.xxx.xxx" is the ELAN network interface IP address of
Leader 0 on the ELAN subnet,

Nortel Communication Server 1000

IP Trunk Fundamentals

NN43001-563

01.01

Standard

Release 5.0

30 May 2007