Appendix C Environmental and electrical regulatory data

Specification

Minimum

Maximum

Recommended

Relative humidity

–50



C

0%

+70



C

95% (non-condensing)

Temperature shock

In three minutes

In three minutes

–50



C

70



C

25



C

25



C

Mechanical conditions

Refer to

Table 80 "Media Card 32-port and ITG-Pentium 24-port trunk

card mechanical specifications" (page 450)

for Media Card 32-port and

ITG-Pentium 24-port trunk card mechanical tolerance ranges.

Table 80
Media Card 32-port and ITG-Pentium 24-port trunk card mechanical specifications

Specification

Minimum

Maximum

Mechanical

Operating

5-200 Hz 0.1 g

Two hours per axis

Non-operating

5-100 Hz 0.5 g
100-200 Hz 1.5 g

30 min. per axis
30 min. per axis

Shock:

Handling
(Packs, unpackaged)

Free fall onto each
face and corner

See IEC 68-2-31,
Test Ec

Bounce

1.2 g, 30 min/surface

See IEC 68-2-31
Test Eb

Handling
(Packs, packaged)

Free fall onto corner,
3 edges, all surfaces

See NSTA Proj 1A

Earthquake

NEBS GR-63-CORE,
Zone 4

Electrical regulatory standards

The following tables list the safety and electromagnetic compatibility
regulatory standards for the IP trunk card, listed by geographic area.
Specifications for the IP trunk card meet or exceed the standards listed
in these regulations.