Install the ntmf94ea cable (for non-dchip cards), Procedure 10 installing the ntmf94ea cable – Nortel Networks NN43001-563 User Manual

Page 197

Advertising
background image

Install NTMF94EA and NTCW84KA cables

197

Figure 36
NTCW84KA ELAN, TLAN, DCH, and serial cable

Install the NTMF94EA cable (for non-DCHIP cards)

Follow the steps in

Procedure 10 "Installing the NTMF94EA cable" (page

197)

to install the NTMF94EA cable for non-DCHIP cards.

Procedure 10

Installing the NTMF94EA cable

Step

Action

1

Connect the NTMF94EA cable (see

Figure 37 "NTMF94EA ELAN,

TLAN and serial port cable" (page 198)

) to the I/O panel connector.

Make sure to connect to the I/O panel connector which corresponds
to the left slot number of the DCHIP card.

2

Secure the mounting screw provided on the top of the Shielded
25-Pair Amphenol Connector to the I/O Panel filter connector in
order to tie the shield of the LAN cable to the frame ground for EMC
compliance.

Nortel Communication Server 1000

IP Trunk Fundamentals

NN43001-563

01.01

Standard

Release 5.0

30 May 2007

Copyright © 2007, Nortel Networks

.

Advertising