Appendix B Cable description and NT8D81BA cable replacement

5

To remove the ribbon cables from the IPE backplane:

a. Apply gentle pressure on the tab on the right side of the shroud

while pulling on the connector until it pulls free from shroud.

b. Remove connector 1 first, then remove connectors 2 and 3.

6

Discard the NT8D81BA cable.

—End—

Install NTCW84JA filter and NT8D81AA cable

Follow the steps in

Procedure 75 "Installing the NTCW84JA filter and

NT8D81AA cable" (page 448)

to install the NTCW84JA filter and NT8D81AA

cable.

Procedure 75

Installing the NTCW84JA filter and NT8D81AA cable

Step

Action

1

Install the NTCW84JA special IPE filter connector in the vacant I/O
panel slot using retained hardware.

2

Install NT8D81AA ribbon cable connectors in the IPE module
backplane shroud. Be sure to install the connector so the label is
facing right with the arrow pointing up and the connector is fully
engaged into the shroud:

a. Install connector 1, (labeled UP1^) into backplane shroud 1.

b. Install connector 2, (labeled UP2^) into backplane shroud 2.

c. Install connector 3, (labeled UP3^) into backplane shroud 3.

3

Dress ribbon cables back individually inside the rear of the IPE
module and restore the original arrangement. Start with the cables
that are going to be underneath.

4

Attach the NTCW84JA special IPE filter to the NT8D81AA 50-pin
connector using bail clips.

5

Restore power to the IPE module.

6

Replace I/O safety panel.

—End—

Nortel Communication Server 1000

IP Trunk Fundamentals

NN43001-563

01.01

Standard

Release 5.0

30 May 2007