Flash storage upgrades, Software upgrade mechanisms, Procedure 69 upgrading software using tm 3.1 – Nortel Networks NN43001-563 User Manual

Page 412

Advertising
background image

412

Maintenance

Command

Description

pnew

The pnew command has no parameter(s).

Patch Directories

There are two patch directories on an IP trunk card:

1. /C:/u/patch

This is the default directory for patch files. Patch files should be copied
to this directory.

2. /C:/u/patch/reten

Use this directory to store patch retention control files. Do not use this
directory to store patches and do not remove files from this directory.

Flash storage upgrades

These are provided through standard 5 Volt ATA-compatible PC Cards.
When installed in an IP trunk card ("hot installation" allowed), the additional
storage provided by the IP trunk card is made available as A:/.

Software upgrade mechanisms

Use TM 3.1 to upgrade software. Reboot the IP trunk card to run the new
software.

Upgrade software using TM 3.1

The new IP Trunk 3.01 (and later) software application can be downloaded
from the TM 3.1 PC to the IP trunk card. Follow the steps in

Procedure 69

"Upgrading software using OTM 2.1 (and later)" (page 412)

to upgrade

software.

Procedure 69

Upgrading software using TM 3.1

Step

Action

1

Download the latest IP Trunk 3.01 (and later) software version from
Nortel. Determine the location on the TM 3.1 PC hard drive where it
is to be loaded. Record the TM 3.1 PC hard drive location for use
later in this procedure. For more detailed instructions on how to
access the latest software version, turn to

"Check and download IP

trunk card software in OTM 2.1 (and later)" (page 271)

.

2

Open TM 3.1 and launch the ITG ISDN IP Trunks application.

Nortel Communication Server 1000

IP Trunk Fundamentals

NN43001-563

01.01

Standard

Release 5.0

30 May 2007

Copyright © 2007, Nortel Networks

.