Nortel Networks NN43001-563 User Manual

Page 274

Advertising
background image

274

Install and configure IP Trunk 3.01 (and later) node

If a mix of Media Card 32-port and ITG-Pentium 24-port trunk
cards is in the same IP Trunk 3.01 (and later) node, then select
all cards of the same density in the lower half of the window.
Hold down the Ctrl key while making individual card selections.

4

Select menu Configuration/Synchronize/Transmit. The ITG -
Transmit Options
dialog box appears.

5

If transmitting new software to a node, choose step a or b.

If transmitting new software to a node containing cards of the
same density, ensure the following:

Make sure Transmit to selected nodes is selected.

Check Card software checkbox.

Click Browse and locate the software file for the card density of
the selected node.

Click Start Transmit. The software is transmitted to each card in
turn and burned into the flash ROM on the IP trunk card. Monitor
the progress of the card software transmission in the Transmit
Control
window. IP Trunk 3.01 (and later) indicates success or
failure of card software transmission by card TN. Scroll to verify
that the transmission was successful for all card TNs. The cards
continue to run the old software until rebooted.

Click the Close button and go to step 6.

If transmitting new software to a node containing a mix of card
densities, ensure the following:

Make sure Transmit to selected cards is selected.

Check Card software checkbox.

Click Browse and locate the software file for the card density of
the selected cards (24-port or 32-port).

Click Start Transmit. The software is transmitted to each card in
turn and burned into the flash ROM on the IP trunk card. Monitor
the progress of the IP trunk card software transmission in the
Transmit Control window. IP Trunk 3.01 (and later) indicates
success or failure of card software transmission by card TN.
Scroll to verify that transmission was successful for all card TNs.
The IP trunk cards continue to run the old software until rebooted.

Click Close button.

Repeat steps 3b, 4 and 5b for the other card density.

Nortel Communication Server 1000

IP Trunk Fundamentals

NN43001-563

01.01

Standard

Release 5.0

30 May 2007

Copyright © 2007, Nortel Networks

.

Advertising