Cabling for the Media Card 32-port trunk card

213

NTMF04BA MSDL extension cable

The NTMF04BA cable connects the NTND26AA MSDL cable and the
NTMF29BA DCHIP cable, when the Common Equipment shelf and the
IPE shelf are in separate columns and not connected by internal cabling
channels. A 15-way mounting block (A03511331) is shipped with the
NTMF04BA cable. The mounting block, when mounted on the Common
Equipment shelf I/O panel, allows the connection of the NTND26AA and the
NTMF04BA cables. The NTMF04BA cable is then routed externally to the
IPE I/O panel to connect with the NTMF29BA DCHIP. See

Figure 47 "Large

system DCHIP cabling setup: inter-column" (page 213)

.

Figure 47
Large system DCHIP cabling setup: inter-column

When the Universal Equipment Modules (UEM) are stacked vertically, or
the UEM columns are bolted together, they are cabled in an inter-column
configuration. See

Figure 47 "Large system DCHIP cabling setup:

inter-column" (page 213)

. This applies when the UEM system columns

are physically separated and the DCHIP must exit the systems through
the I/O panel.

DCHIP Cable Routing
Meridian 1 Option 11C Cabinet/CS 1000M Cabinet

The following cables are specific to Meridian 1 Option 11C Cabinet/CS
1000M Cabinets. Cable connection details are shown in

Figure 48 "Option

11C DCHIP system cabling" (page 214)

.