Install shielded elan network interface cable, Required cables and filters for large systems, Configure nt6d80 msdl switches – Nortel Networks NN43001-563 User Manual

Page 199

Advertising
background image

Configure NT6D80 MSDL switches

199

When connecting the Media Card 32-port trunk card and/or ITG-Pentium
24-port trunk card to the TLAN subnet, the link status LED on the card
faceplate associated with the TLAN network interface lights green when the
connection is made. The link status LED on the hub port also lights green
when connected to the IP trunk card.

Install shielded ELAN network interface cable

For DCHIP cards

Connect a shielded CAT5 LAN cable from the ELAN subnet hub to the
RJ-45 coupler on the NTCW84KA ELAN network interface.

For non-DCHIP cards

Connect a shielded CAT5 LAN cable from the ELAN subnet hub to the
RJ-45 coupler on the NTMF94EA ELAN network interface.

There are no ELAN network status LEDs for the ELAN network interface
on the Media Card 32-port trunk card and ITG-Pentium 24-port trunk card.
When connected to the IP trunk card ELAN network interface, the port
status LED indicator on the ELAN subnet hub lights green to indicate a
good connection.

D-channel cabling for the NT0961AA ITG-Pentium 24-Port trunk card

In this section, check, and reset if necessary, MSDL switch settings, install a
filter (if required for the installation) and install the cable that connects the
MSDL or SDI/DCH card to the IP trunk card that provides the DCH interface.

Required cables and filters for Large Systems

Large Systems require the following:

the NTCW84KA ELAN, TLAN, RS-232 and DCH Ports cable

the NTND26AA MSDL DCH cable

Configure NT6D80 MSDL switches

Configure the switches in the NT6D80 MSDL card as shown in

Table 44

"NT6D80 MSDL settings for ITG-Pentium 24-port trunk card DCHIP" (page
199)

.

Table 44
NT6D80 MSDL settings for ITG-Pentium 24-port trunk card DCHIP

Port 0 – SW4

Port 0 – SW8

RS-422-A DTE

all off

all on

The device number for the MSDL card is configured in LD 17 at the prompt DNUM. Also configure
the device number, using switches S9 and S10, on the MSDL card. S9 designates ones and S10
designates tens. To configure the device number as 14, for example, set S10 to 1 and S9 to 4.

Nortel Communication Server 1000

IP Trunk Fundamentals

NN43001-563

01.01

Standard

Release 5.0

30 May 2007