Access the ITG shell through a maintenance port or Telnet

367

Access the ITG shell from the TM 3.1 PC. Refer to

"Telnet to an IP trunk

card through the OTM PC" (page 368)

for details.

Connect a PC to the card maintenance port

Follow the steps in

Procedure 60 "Connecting a PC to the IP trunk card

maintenance port" (page 367)

to connect a PC to the IP trunk card

maintenance port.

Procedure 60

Connecting a PC to the IP trunk card maintenance port

Step

Action

1

To access the ITG shell, connect a PC to the RS-232 serial
maintenance port through DIN-8 connector on the faceplate of the
ITG Leader 0 card with an NTAG81CA PC Maintenance cable. If
required, use an NTAG81BA Maintenance Extender cable to provide
an extension between the NTAG81CA PC Maintenance cable and
the TM 3.1 PC.

Alternatively, for the ITG-Pentium 24-port trunk card, connect
the NTAG81BA Maintenance Extender cable to the female DB-9
connector of the NTCW84KA ELAN, TLAN, DCH, and Maintenance
Port cable (for DCHIP cards), or the NTMF94EA ELAN, TLAN,
Maintenance Port cable (for non-DCHIP cards), to create a more
permanent connection to the IP trunk card serial maintenance port.

For the Media Card 32-port trunk card, a serial connection can be
established by using the DB-9 connector located on the "L-Adaptor"
A0852632.

Never connect two terminals to the front and back serial maintenance
port connectors at the same time.

2

Use the following communication parameters for the TTY terminal
emulation on the PC:

9600 baud

8 bits

no parity bit

one stop bit

3

When prompted to login, enter current username and password.
Default is:

VxWorks login:

itgadmin

Password:

itgadmin

ITG>