Install and configure IP Trunk 3.01 (and later) node

5

Connect the DCH (P5) connector of the NTCW84KA to the outward
side of the 15-pin I/O panel filter connector.

—End—

Install filter and NTND26 cable (for MSDL and DCHIP cards in
different Large System equipment rows)

Follow the steps in

Procedure 12 "Installing the filter and NTND26 cable

for MSDL and DCHIP cards in different Large System equipment " (page
202)

to install the filter and NTND26 cable for MSDL and DCHIP cards in

different Large System equipment rows.

Procedure 12

Installing the filter and NTND26 cable for MSDL and DCHIP cards in different
Large System equipment rows

Step

Action

1

Install the bracket for the 15-pin I/O panel filter connector in the J16,
J17, J37 or J38 I/O panel opening of the I/O panel of the Network
Module or Core/Net Module that contains the MSDL card.

2

Install the 15-pin I/O panel filter connector on the inward side of
the bracket.

3

Obtain the correct length of the NTND26 DCHI Interface Cable
Assembly to reach from the D-Channel port connector on the
faceplate of the MSDL card to the outward side of the 15-pin filter
connector installed in the I/O panel of the IPE Module that contains
the DCHIP card.

The NTND26 DCHI Interface Cable Assembly is available in the
following lengths:

NTND26AA – 6 ft.

NTND26AB – 18 ft.

NTND26AC – 35 ft.

NTND26AD – 50 ft.

4

Connect the appropriate NTND26 cable assembly to the D-Channel
port connector on the faceplate of the MSDL card and to the outward
side of the 15-pin filter connector installed in the I/O panel of the IPE
Module that contains the DCHIP card.

Nortel Communication Server 1000

IP Trunk Fundamentals

NN43001-563

01.01

Standard

Release 5.0

30 May 2007