Install and configure IP Trunk 3.01 (and later) node

Prompt

Response

Description

DIP

Dial Pulse is required for IP Trunk 3.01 (and later) to avoid
busying multiple Digitone receivers when IP trunk card
faults occur.

Trunks must always be set to DIP. If SIG0 = ESN5 in the
RDB, the
Meridian 1/CS 1000M does not allow CLS = DIP in LD 14.
To avoid this problem and retain ESN5 signaling, set SIG0
= STD in RDB (LD 16). Then provision CLS = DIP in LD
14 for IP Trunk 3.01 (and later). After all trunks have been
programmed, in LD 16 change the RDB back to SIG0 =
ESN5.

...

Use the "NEW XX" command to assign DES equal to the IP trunk card
ELAN network interface IP address; for example: 10.1.1.1. For unit 0, use
CHG command to assign DES equal to the IP trunk card ELAN network
interface MAC address; for example: 00:60:38:01:06:C6. To find the ELAN
network interface MAC address, refer to the IP Trunk 3.01 (and later)
Installation Summary Sheet. The ELAN network interface MAC address
is labeled on the IP trunk card faceplate as the "motherboard Ethernet
address." Alternatively, use the ITG shell command "ifShow" to display the
Ethernet address for lnIsa (unit number 0).

Configure dialing plans within the corporate network

Configure the dialing plan by programming LDs 86, 87, and 90 as required.

Configure the Meridian 1/CS 1000M ESN by creating or modifying data
blocks in LDs 86, 87, and 90, as required. The Meridian 1/CS 1000M and
TM 3.1 IP Trunk 3.01 (and later) dialing plan information must correspond.

Make the IP Trunk 3.01 (and later) the first-choice, least-cost entry in
the Route List Block

When adding IP Trunk 3.01 (and later) TIE trunks to an existing ESN,
a common practice is to create a new Route List Block (RLB) for ESN
translations that are to be routed by the IP Trunk 3.01 (and later) network.
Insert the new IP Trunk 3.01 (and later) route ahead of the existing alternate
routes for circuit-switched facilities, which are therefore shifted to the next
higher entry number. Increment the ISET (initial set) if Call-Back Queueing
or Expensive Route Warning tone are being used.