Appendix G Upgrade an ITG Trunk 1.0 node to support ISDN signaling trunks

Procedure 81

Installing the DCHIP I/O Panel breakout cable from the upgrade kit

Step

Action

1

For the Large System, locate the I/O connector that corresponds to
the leftmost card slot of the ITG 8-port trunk card that is undergoing
the hardware upgrade.

2

Disconnect existing ELAN network interface and serial cables.
Remove the existing I/O panel breakout cable.

3

Install the new cable (NTCW84LA or NTCW84MA). Be sure to use
the screw provided.

4

Reconnect ELAN network interface and serial connectors. For
NTCW80CA cards, install a shielded TLAN cable.

5

Turn to

"Install filter and NTND26 cable (for MSDL and DCHIP cards

in same Large System equipment row)" (page 200)

to install the

DCHIP connector and MSDL cable.

—End—

Upgrade the ITG 8-port trunk card ITG basic trunk software to
ITG/ISL trunk software

Use the TM 3.1 ITG Basic Trunk application to perform this procedure.
Once TM 3.1 has been upgraded to 6.6 or later, all the configuration data
for the ITG trunk node will have been converted.

Step 1 - Remove ITG Trunk 1.0 configuration files

Follow the steps in

Procedure 82 "Removing the ITG Trunk 1.0 configuration

files" (page 476)

to remove the ITG 1.0 Trunk configuration files from the

TABLE, BOOTP and CONFIG directories of every card in the node to be
upgraded.

Procedure 82

Removing the ITG Trunk 1.0 configuration files

Step

Action

1

From the TM 3.1 IP Telephony Gateway - ISDN IP Trunk Main
window, select the card from the lower half of the window and
right-click. A context menu appears. Select Telnet to ITG card. TM
3.1 automatically launches a Telnet session to the selected card.