Installation

2. Setting the proximity switches (depending on the control function):

Bottom.end.position.for.control.function.A.or.top.end.position.for.control.function.B

→

Switch on supply voltage at the proximity switch connector.

→

Using a screwdriver, set proximity switch at the setting screw to end position.

→

→

→→Switch off supply voltage at the proximity switch connector.

Bottom.end.position.for.control.function.I

→

Connect the pilot air.

WarninG!

Valve.moves.after.electrical.voltage.has.been.connected!

After connecting the electrical voltage, the actuator moves to the set end position!

• Never perform setting of the proximity switch while a process is running!

→

Switch on supply voltage at the positioner and proximity switch connector.

→

Move actuator to the bottom end position.

→

Using a screwdriver, set proximity switch at the setting screw to end position.

→

→

→→Switch off the pilot air.

→

→

→→Disconnect supply voltage at the positioner and proximity switch connector.

Top.end.position.for.control.function.A.and.I.or.bottom.end.position.for.control.function.B

→

Set jumper (see “Figure 30: Setting the proximity switches”).

→

Connect the pilot air.

WarninG!

Valve.moves.after.electrical.voltage.has.been.connected!

After connecting the electrical voltage, the actuator moves to the set end position!

• Never perform setting of the proximity switch while a process is running!

→

Switch on supply voltage at the positioner / process controller and proximity switch connector.

→

Move actuator to the top end position (CFA and I) or bottom end position (CFB).

→

Using a screwdriver, set proximity switch at the setting screw to end position.

→

→

→→Switch off the control air.

→

→

→→Switch off supply voltage at the unit and the proximity switch connector.

→