Overview of operating structure initial start-up – Burkert Type 8693 User Manual

Page 75

Advertising
background image

75

Installation

19.3.3. Overview of operating structure initial start-up

Operating state

AUTOMATIC

or

MANUAL

MENU

ACTUATOR

INPUT

X.TUNE

ADD.FUNCTION

SAVE

EEPROM

SELEC

4-20 mA

EXIT

ENTER

approx. 3s

RUN approx. 5s

X.TUNE

STARTED

TUNE

#0INIT

X.TUNE

READY

EXIT

0-20 mA

0-10 V

0- 5 V

EXIT

Main menu

MAIN

Selection menu

(

ACTUATOR, INPUT, ...)

Operate process

Configuration

Operating mode of the
actuator preset at the factory

not required for the initial
start-up

Selection of the input signal

Self-parameterization

Figure 35:

Operating structure - initial start-up

english

Type 8692, 8693

Advertising
This manual is related to the following products: