NOTE: When performing multiple step Angle control fastening, the rotation Angle should be

performed as one continuous operation. There should be no intermediate stop

tion points once Snug Torque has been sensed and rotation angle is being controll

Under special conditions multiple steps can be performed using intermediate Torque or Angle

stop/synchronization points

FIG. 6

Snug Torque

Threshold Torque

Speed Change Torqu

Crossover Torque

Operations Manual Chapter 6: Fastening Instructions (Rev.

Page 6-11

When performing multiple step Angle control fastening, the rotation Angle should be

performed as one continuous operation. There should be no intermediate stop

tion points once Snug Torque has been sensed and rotation angle is being controll

Under special conditions multiple steps can be performed using intermediate Torque or Angle

stop/synchronization points as shown below.

FIG. 6-1-2d Angle Control Functions for Three-Step Fastening

1

st

Time

Final Time

Standard

Angle

Snug Torque

Threshold Torque

Speed Change Torque

1

st

Torque

Crossover Torque/Angle

Chapter 6: Fastening Instructions (Rev. 2)

When performing multiple step Angle control fastening, the rotation Angle should be

performed as one continuous operation. There should be no intermediate stop / synchroniza-

tion points once Snug Torque has been sensed and rotation angle is being controlled.

Under special conditions multiple steps can be performed using intermediate Torque or Angle

Step Fastening