Chapter 9: Troubleshooting

Page 9-4

9.2.3

Code 1-2 TORQUE TRANSDUCER / ZERO CHECK ERROR

Zero level voltage loaded to memory from tool EEPROM during initialization does not match

the actual zero level during a self check with the self check function DISABLED.

This abnormal is caused from;.

1. When the tool transducer is sensing excessive torque due to pressure or vibration during

the fastening cycle start.

2. If the controller or the transducer cable is located in an electric or magnetic noise field.

3. When the torque transducer, Tool cable or the controller malfunctions.

RECOVERY:

1. Check that the tool has no external force applied to it.

2. Verify the tool mounting bolts are tight and nothing is cause excessive vibration to the tool.

3. Verify that the cable or controller is not located near any high voltage transient power

sources. Relocate as required and attempt again the fastening start input.

4. Exchange tool cable, tool and/or controller with known working units. Input the start signal

after each exchange, and make note of any change in the location of the abnormal.

5. Replace the defective component.

9.2.4 Code 1-3 TORQUE TRANSDUCER / CAL SELF CHECK ERROR

Calibration level voltage error after a fastening start was attempted.

This abnormal is caused from;

1. When the tool transducer is sensing excessive torque due to pressure or vibration during

the fastening cycle start.

2. If the controller or the transducer cable is located in an electric or magnetic noise field.

3. When the torque transducer, Tool cable or the controller malfunctions.

RECOVERY:

1. Check that the tool has no external force applied to it.

2. Verify the tool mounting bolts are tight and nothing is cause excessive vibration to the tool.

3. Verify that the cable or controller is not located near any high voltage transient power

sources. Relocate as required and attempt again a fastening start input.

4. Exchange tool cable, tool and/or controller with known working units. Input the start input

after each exchange, and make note of any change in the location of the abnormal.

5. Replace the defective component.

9.2.5

Code 1-4 TORQUE TRANSDUCER /STARTED ON ZERO ERROR CONDITION

The start signal was input while a Zero voltage abnormal condition existed.

RECOVERY:

1. Interlock the PLC circuit to disable the start signal during an existing abnormal condition.

2. Follow the ZERO VOLTAGE ERROR abnormal help procedure.

9.2.6 Code 1-5

TORQUE TRANSDUCER / STARTED ON CAL ERROR CONDITION

The start signal was input while a Cal voltage abnormal condition existed.

RECOVERY:

1. Interlock the PLC circuit to disable the start signal during an existing abnormal condition.

2. Follow the CAL VOLTAGE ERROR abnormal help procedure.