FEC Fusion Operations Manual Chapter 6: Fastening Instructions (Rev. 2)

Page 6-27

6.6.6 Torque Inhibit

The Torque Inhibit function is used to ignore high torque spikes during initial starting of the motor or

fastening process. Under normal fastening operations, peak torque will stop the fastening process (if

Standard Torque is reached). This may not be desirable for applications with high starting torque and

lower fastening torque. Applications such as self tapping screws, nylok nuts, crushed fasteners, and

application with high starting inertia may require this function.

Torque Inhibit is set by the number of revolutions that is required to be “ignored” during the process.

The Torque Inhibit Limit is a torque limit used as protection in case the amount of torque monitored

during the Torque Inhibit Revolution is too high. If this torque limit is hit during the Torque Inhibit

process, then the spindle will stop and an Abnormal is output.

Fig. 6-6-9 Torque Inhibit Function

WARNING: The Torque Inhibit Rev setting should be set as low as possible for the intended

application to avoid ignoring torque readings as the fastener approaches the seating point. If

the fastener seats and the system is still in Torque Inhibit mode, possible fastener/part and/or

system damage may occur.

Speed

Initial

Initial Time

Torque

Slow Down

Freerun

Torque Inhibit

Revolutions

Freerun

Revolutions

1

st

Time