Profibus Signal I/O Map

(Continued)

Word

Byte

Bit No.

Signal Description

Comment

4

8

0

65

Angle Integer bit 0

Outputs Fastening Angle value using

binary integer

0 - 9999 max.

Example:

bit 1, 2, 5, 7 Logical "1" = 166

1

66

Angle Integer bit 1

2

67

Angle Integer bit 2

3

68

Angle Integer bit 3

4

69

Angle Integer bit 4

5

70

Angle Integer bit 5

6

71

Angle Integer bit 6

7

72

Angle Integer bit 7

9

0

73

Angle Integer bit 8

1

74

Angle Integer bit 9

2

75

Angle Integer bit 10

3

76

Angle Integer bit 11

4

77

Angle Integer bit 12

5

78

Angle Integer bit 13

6

79

7

80

5-7

Byte

10-15

81

Not Used

128

From PLC to Fusion: 2 Words (4 Bytes – 32bits)

Word Byte Bit No. Description

Comment

0

0

0

1

1

2

2

3

3

4

4

5

5

6

6

7

Abort Job

Reserved for Future Use

7

8

Reset

1

0

9

1

10

2

11

3

12

4

13

Work Select/Job 0

Job Function is Future

5

14

Work Select/Job 1

Job Function is Future

6

15

Work Select/Job 2

Job Function is Future

7

16

Work Select/Job 3

Job Function is Future

1

2

0

17

Stop

1

18

Reset

2

19

Reverse

3

20

Start

4

21

Bypass

5

22

Disable Self-check

6

23

7

24

3

0

25

1

26

2

27

3

28

4

29

In 12

Terminal Input 12 not assigned

5

30

In 13

Terminal Input 13 not assigned

6

31

In 14

Terminal Input 14 not assigned

7

32

In 15

Terminal Input 15 not assigned

`