FEC FUSIONE-HS-2 User Manual

Page 180

Advertising
background image

Chapter 9: Troubleshooting

Page 9-12

9.9.4 Code 8-6

SERVO AMPLIFIER ERROR / INPUT VOLTAGE ABNORMAL

The CONTROLLER servo power supply circuit has detected improper input voltage either

above or below the specified limits

This abnormal is caused from;

1. The controller internal power supply has failed

2. Source voltage is out of the limit and/or the environment temperature is also close to the

limit.

3. One or more phases of input power is missing

RECOVERY:

1. Replace the controller

2. Provide additional cooling to the enclosure.

3. Verify and correct the source voltage as required.

9.9.5 Code 8-9

SERVO AMPLIFIER ERROR/ OVER SPEED.

The resolver signal received at the CONTROLLER indicates an over speed condition.

This abnormal is caused from;

1. The resolver cable or resolver has failed.

RECOVERY:

1. Check resolver using method in 8.2.2

2. Replace resolver cable to spare cable

3. Replace tool assembly.

9.9.6 Code 8-10

SERVO AMPLIFIER ERROR / OVER LOAD ( I SQUARE T)

The duty cycle of the fastening application is too severe for this size of tool, or for the para-

meters currently setup.

RECOVERY:

1. Reduce duty cycle - Increase tool “downtime or off time” and/or increase torque speed to

reduce the amount of time running at high torque/slow speed.

2. If the problem remains, a larger tool assembly may be required for this application. Please

contact FEC.

9.9.7 Code 8-11

SERVO AMPLIFIER ERROR

/

RESOLVER SIGNAL ERROR.

The resolver signal received is not correct.

RECOVERY:

1. Check the cable; look for loose connectors for visible damages to the cable.

2. Replace with known good tool.

Advertising