FEC FUSIONE-HS-2 User Manual

Page 109

Advertising
background image

FEC Fusion Operations Manual Chapter 6: Fastening Instructions (Rev. 2)

Page 6-13

For Angle Control operations, the High and Low Torque limits are either set by the engineer-

ing specification for that specific fastener, or by determining the acceptable limits from a

study of known good and bad assemblies. The High Torque limit will stop the fastening

process for Angle Control operations if it is reached before attaining the desired angle.

ANGLE CONTROL

REJECT TYPE

CAUSES

PEAK TORQUE HIGH LIMIT

Reduced joint compression.

Increased joint friction.

Incorrect parameter set-up.

PEAK TORQUE LOW LIMIT

Increased joint compression.

Reduced joint friction.

High initial prevailing torque.

Incorrect parameter set-up.

Reject condition caused by another monitor item reject.

FIG. 6-2-1b Peak Torque Monitor – Angle Control

Snug Torque

Threshold Torque

Speed Change Torque

1

st

Torque

Crossover Torque

Final Time

1

st

Time

Standard

Angle

Torque

Angle/Time

Peak Torque High Limit

Peak Torque Low Limit

Advertising