FEC Fusion Operations Manual Chapter 6: Fastening Instructions (Rev. 2)

Page 6-19

FIG. 6-2-4a Two Stage Point-to-Point Torque Rate Monitoring

FIG. 6-2-4b Three Stage Point-to-Point Torque Rate Monitoring

Crossover Torque

Torque

Angle/Time

1

st

Time

Final Time

2

nd

Rate Start Torque

Standard Torque

Threshold Torque

1

st

Torque

1st Rate

Low Limit

2nd Rate

High Limit

1st Rate

High Limit

2nd Rate

Low Limit

Torque

Angle/Time

1

st

Time

Final Time

2

nd

Rate Start Torque

Standard Torque

Threshold Torque

1

st

Torque

1ST Rate

Low Limit

3rd Rate

High Limit

2nd Rate

High Limit

1st Rate

High Limit

2nd Rate

Low Limit

3rd Rate

Low Limit

Crossover Torque

Advertising