FEC FUSION Operations Manual

Chapter 4: System Setup and Wiring (Rev. 2.1)

Page 4-15

BANK

SEL.

INPUT

PLC / CONTROLLER UNIT BANK DATA

BANK

NO.

SEL 1

B4

SEL 0

A4

Output

A11~B14

NAME OF

SIGNAL

DESCRIPTION

WORK 3

NOT USED

3

ON

OFF

ANGLE HIGH

REJECT

Output when Fastening resulted in an Angle

High Reject.

ANGLE LOW

REJECT

Output when Fastening resulted in an Angle

Low Reject.

1ST RATE

HIGH

REJECT

Output when Fastening resulted in a 1st

Torque Rate High Reject.

1ST RATE

LOW

REJECT

Output when Fastening resulted in a 1st

Torque Rate Low Reject.

2ND RATE

HIGH

REJECT

Output when Fastening resulted in a 2nd

Torque Rate High Reject.

2ND RATE

LOW

REJECT

Output when Fastening resulted in a 2nd

Torque Rate Low Reject.

NOT USED

NOT USED

4

ON ON

ZERO CAL

ERR

Outputs when an abnormal condition occurs

during the SELF CHECK (CAL and Zero).

PSET ERR.

Outputs when an abnormal condition occurs in

the parameter setting.

RES ERR

Outputs when an abnormal condition occurs in

the resolver.

TOOL ERR

Outputs when a tool related abnormality

occurs.

SV AMP ERR

Outputs when a servo abnormality occurs, see

SV ERR 0~2 codes below.

SV ERROR 0

Outputs a detailed code when a SV AMP ERR

is output. Error code is output in three bits.

(See Section 4.7.4 ).

SV ERROR 1

SV ERROR 2