FUSION Operations Manual Chapter 7: System Operations (Rev.2)

Page 7-35

7.

Initial Time [WORK]-01(thru-16), [D-No]-40

Set Initial Time so that revolution time/speed is slow during motor start-up

(the time that the socket is rotating in the socket “U” opening)

Recommended setting: .3sec

8.

Initial Speed [WORK]-01(thru-16), [D-No]-50

Set Initial Speed for slow rotation while socket is rotating through the “U”

opening.

Recommended setting: 60rpm max.

9.

Reverse Speed [WORK]-01(thru-16), [D-No]-54

Reverse speed is used to re-align the socket after a fastening.

Recommended setting: 80 – 100rpm max.

10.

Ramp Up Time [WORK]-01(thru-16), [D-No]-45

Sets motor ramp-up time from slow to higher speeds

Recommended setting: 1.0 – 1.5sec.

(Can only be set in Supervisory security mode)

11.

Ramp Down Time [WORK]-01(thru-16), [D-No]-46

Sets motor ramp-down time from high to slower speeds

Recommended setting: 1.0sec.

(Can only be set in Supervisory security mode)

7.6.2 Tubenut Head Operation

When using a Tubenut head, a special function is required to re-align the socket after normal

fastening operations and allow the socket to be placed onto the nut to be fastened. The start

trigger must be held “ON” for the complete fastening of the part. If the trigger is released dur-

ing the fastening cycle, the fastening will stop. The fastening can be re-started by simply

squeezing the trigger again. Use the procedures below to re-align the Tubenut socket.

First Time Power-Up / Socket Re-alignment

If the Tubenut socket is not aligned use the following procedure to re-align the open socket.

Press the “Reverse” pushbutton (Tool RED / GREEN LED’S will flash)

Press the start trigger

Hold the start trigger until the socket is re-aligned and the tool shuts off (tool au-

tomatically shuts off)

NOTE

: If the socket is turning in the wrong direction to re-align the head (Re-alignment must

turn CCW for proper operation), the Gear Head Selection is wrong ([WORK]-00, [D-No]-05).

Return to Home Position after Fastening

After fastening a part, the tubenut socket must be re-aligned in order to remove it from the

part. Use the procedure above to re-align the socket if removal is desired. Use this proce-

dure to re-align the socket and remove the head from the part after a complete fastening.

Hold down start trigger until fastening is complete

While still HOLDING the start trigger after fastening is complete, lift socket off of

the nut being fastened

Release start trigger and the socket will re-align automatically.

If the trigger is inadvertently released before the socket is re-aligned, follow the

procedure above to re-align the socket.