FEC FUSIONE-HS-2 User Manual

Page 132

Advertising
background image

Chapter 7: System Operations

Page 7-8

7.2.4 Parameter Display Mode

The FUSION system can store up to 16 different sets of parameters that can be selected for fastening

operations via the

[ ] and [ ]

keys (Horizontal arrows) or by PLC input signals WORK SELECT 0 ~

3 (see section 4.7.2.) In addition to parameter 1 ~ 16 there is a PARAMETER 0 that contains confi-

guration data common to all parameters.

Parameter display mode

displays the preset values programmed in the CONTROLLER unit for fas-

tening operation. When parameter display mode is enabled, the [COUNT/D-NO] display will show 2

digits (00-73) representing the preset data number. The [DATA] display will show the corresponding

preset data value and the parameter display will indicate the parameter number (from 0 ~ 16). Use

the [

↓↓↓↓

] and [

↑↑↑↑

] keys to change the preset data number [D-NO]. If the [COUNT/D-NO] display is show-

ing the number 74 of the

parameter number 1

, pressing the [

↑↑↑↑

] key will change the [COUNT/D-NO]

display to the number 00 of the

parameter number 2

.

You can verify the fastening parameters by pressing the [

↓↓↓↓

] and [

↑↑↑↑

] keys at any time. However, it is

not possible to alter these settings in the

Run state

.

Note: Representation only, not actual data

FIG. 7-2-4a Parameter number selection

Parameter

No.16

Parameter

No.15

Parameter

No.14

Parameter

No.03

Parameter

No.02

Parameter

No.01

00: Fastening Mode

10: Calibration tor-

que

11: Peak Low Tor-

que

12: Peak High Tor-

Parameter

No.00

System Para-

meter

00: Torque Unit

01: NR Version

02: Amplifier Version

03: Function Version

Advertising