3 fastening results display mode – FEC FUSIONE-HS-2 User Manual

Page 131

Advertising
background image

FUSION Operations Manual Chapter 7: System Operations (Rev.2)

Page 7-7

7.2.3 Fastening Results Display Mode.

In

Fastening results display mode

(when [COUNT/D-NO] shows

_0

~

≡≡≡≡6666

), data can be ob-

tained by pressing the [

↓↓↓↓

] and [

↑↑↑↑

] keys to scroll the [COUNT/D-NO] until the desired DATA

item is displayed. The following information will be displayed in the [DATA] display section

for the displayed [D-NO]:

D-No

DATA

_0

PEAK TORQUE.

_1

FINAL ANGLE

_2

1ST TORQUE RATE

_3

2ND TORQUE RATE.

_4

1ST STEP TIME.

_5

FINAL STEP TIME.

_6

CYCLE TIME

_7

FASTENING MODE.

_8

3RD TORQUE RATE

_9

NOT USED

====0

FASTENING MODE.

=1

FASTENING STEPS

=2

NOT USED

=3

SELF CHECK (ON: enabled, OFF: disabled)

=4

REVERSE FLAG (ON:Reversed, OFF: Not Reversed

=5

CAUSE OF FASTENING STOP:

0: RESET / NO DATA / AFTER REVERSE.

1: ABNORMAL SIGNAL.

2: BYPASS SIGNAL.

3: STOP SIGNAL.

4: REJECT.

5: ACCEPT.

=6

TORQUE JUDGE tq H/L (FINAL) H/L (PEAK)

=7

ANGLE JUDGE AN H/L

=8

RATE JUDGE r H/L (1ST) H/L (2ND) H/L (3RD)

=9

TIME JUDGE ti H/L (1ST) H/L (FINAL)

≡≡≡≡0

1ST INCREMENT TORQUE.

≡≡≡≡1

2ND INCREMENT TORQUE.

≡≡≡≡2

1ST FINAL TORQUE

≡≡≡≡3

1ST PEAK TORQUE.

≡≡≡≡4

FINAL TORQUE.

≡≡≡≡5

ANGLE AT PEAK TORQUE

≡≡≡≡6

PEAK CURRENT

FIG. 7-2-3 Fastening results display selection