Chapter 7: System Operations

Page 7-20

Data No.20 Low Angle

[deg]

Data No.21 High Angle

[deg]

Setting range: 0~9999

Sets the High and Low limits for Fastening Judgment Angle as measured from [16:SNUG Tor-

que] to Fastening End. If the High limit is reached the fastening operation will stop even if the

operation is not complete.

Data No.22 Standard Angle

[deg]

Setting range: 0~9999

Sets the target Angle value for fastening as measured from [16:SNUG Torque].

This is only available when [00: Fastening Mode] is Angle Mode.

Data No.25 Correction Angle

[deg]

Setting range: 0~99

Compensation value for when the Final Angle value of the equipment does not match the value

read from an external master device.

Normally, this value shall be set as 0.

Data No.30 1

st

Rate Low Limit

[Nm/deg]

Data No.31 1

st

Rate High Limit

[Nm/deg]

Setting range: 0~Tool type’s maximum torque rate

Sets the high and low limits for the Torque rate measured between the two points

[17:Threshold Torque] and [15:1ST Torque] or [23:1

st

Angle].

Judgment is conducted at the point when [15:1ST Torque] or [23:1

st

Angle] is achieved or when

Fastening ends, whichever occurs first.

Data No.32 2

nd

Rate Low Limit

[Nm/deg]

Data No.33 2

nd

Rate High Limit

[Nm/deg]

Setting range: 0~Tool type’s maximum torque rate

Sets the high and low limits for the Torque rate measured between the two points

[1E:2

nd

Rate Start Torque] or [26:2

nd

Rate Start Angle] and [18:CROS Torque] or

[24:CROS Angle].

Judgment is conducted at the point when the [18:CROS Torque] or [24:CROS Angle] is

reached or when Fastening ends, whichever occurs first.

Data No.34 3

rd

Rate Low Limit

[Nm/deg]

Data No.35 3

rd

Rate High Limit

[Nm/deg]

Setting range: 0~Tool type’s maximum torque rate

Sets the high and low limits for the Torque rate measured between the two points

[18:CROS Torque] or [24:CROS Angle] and Fastening End.

Data No.40 Initial Time

[sec]

Setting range: 0 ~ 999.9

During initial time, the start of the fastening operation will be conducted at [50: Initial Speed]

When [40 Initial Time] is set as 0, the operation will start in [51: Freerun Speed]

Data No.41 1ST Time High Limit

[sec]

Setting range: 0~999.9

Set the high time limit between the start of fastening and [15: 1ST Torque] or [23: 1ST Angle].

When this time elapses before reaching the target, the process is rejected.

Data No.42 Final Time High Limit

[sec]

Setting range: 0~999.9

Set the high time limit between [15:1ST Torque] or [23: 1ST Angle] and Fastening end

When this time elapses before reaching the target, the process is rejected.