Chapter 7: System Operations

Page 7-18

Data No.18 CROS Torque

[Nm, Kgm...]

Setting range: 0 ~ [10: Calibration torque] × 1.0

2nd stop / synchronization point for multiple step fastening operations.

End point for 2nd torque rate calculation. [1E: 2

nd

Rate Start Torque is beginning]

Start point for 3

rd

Torque Rate calculation. [Fastening End is the stop point]

Data No.24 CROS Angle

[deg]

(NOT USED as standard function)

Setting range: 0 ~ 9999

2nd stop / synchronization point for multiple step fastening operations.

End point for 2nd torque rate calculation. [1E: 2

nd

Rate Start Torque or 26: 2

nd

Rate Start Angle

is the beginning]

Start point for 3

rd

Torque Rate calculation. [Fastening End is the stop point]

Data No.19 Torque Inhibit Limit

[Nm, Kgm...]

Setting range: 0 ~ [10: Calibration torque] × 1.1

Limit for ignoring the Torque value sensed during fastening start due to inertia. When the initial

Torque exceeds the Torque Inhibit Limit during [61: Torque Inhibit Revolutions] an ABNORMAL

will be generated and fastening will end.

Data No.1A Not Used

Data No.56 Not Used

Angle

Torque

34 Rate 3 Low Limit

35 Rate 3 High Limit

24 CROS

22 Standard

Torque

Angle

13 Standard

18 CROS

34 Rate 3 Low Limit

35 Rate 3 High Limit

If 3rd

t

Torque Rate monitoring is not required, [18:CROS Torque] should be set the

same or higher than [10: Calibration Torque]