Page 7-2

7.1 FUSION Display and Programming unit operation.

The FUSION system can be programmed and monitored using the AFC Software package or

through use of the keypad and LED display on the front panel. While the AFC software offers

an easy to use Windows based software, especially for multiples of spindles, the keypad and

display offer an economical alternative.

FIG. 7-1 Operational controls and indicators

7.1.1 Manual Fastening controls.

START

The Start switch for the FUSION Controller is located on the Handheld tool. This Trigger-

switch initiates the fastening cycle. When partially depressed, the tool will run in a slow start

speed; until the trigger is fully depressed, until the trigger is released, or until the fastening

cycle is complete. When the trigger is fully depressed the tool will operate as programmed,

completing each speed change step that has not elapsed.

(Alternative Start input available though use of PLC inputs on terminal TB1)

REVERSE

The Reverse switch for the FUSION Controller is located on the Handheld tool. This push-

button switch enables Reverse/back-out operations. When depressed, the Tool LED display

will flash to indicate Reverse/back-out mode selection. Depressing the Start trigger switch,

while in Reverse/back-out mode, will cause the tool to run the opposite direction of the Fas-

tening operation

(Alternative Reverse input available though use of PLC inputs on terminal TB1)