4.10 Controller Unit DIP Switch

In a multiple controller u

zational purposes. The number is set using the DIP switch located

on the back panel of the unit.

DIP switch located on printed

circuit board through access

panel at the back of unit.

4.10.1 Controller Unit DIP Switch positions 1 ~ 3

DIP switch positions 1 ~ 3 are used for setting the special configuration features as defined in the

following explanation. The DEFAULT setting is switch 1

DIP Switch 1 -

Zero Check

o

ON – Expanded Zero

o

OFF – Normal Zero

DIP Switch 2 -

NOT USED

o

ON – Not Used

o

OFF – Not Used

DIP Switch 3 -

Disable Motor Ramp Down

o

ON - Enables dynamic brake for motor speed changes.

- Used for applications which overshoot standard torque

- Will reduce Motor/Tool life

o

OFF - Disables Dynamic brake during speed changes (Default)

Note: The Controller unit must be powered off and on

initialized.

FEC FUSION Operations Manual

Chapter 4: System Setup and Wiring (Rev. 2.1)

Page 4-27

Unit DIP Switch Setting.

controller unit system, it may be beneficial to address the controllers

purposes. The number is set using the DIP switch located behind the access panel

of the unit.

DIP switch located on printed

ircuit board through access

anel at the back of unit.

FIG. 4-10 Dip Switch settings

Unit DIP Switch positions 1 ~ 3

DIP switch positions 1 ~ 3 are used for setting the special configuration features as defined in the

. The DEFAULT setting is switch 1 – 3 OFF.

Check acceptance window selection

.

Zero Check acceptance window

Zero Check acceptance window

NOT USED

Disable Motor Ramp Down

.

Enables dynamic brake for motor speed changes.

Used for applications which overshoot standard torque

Will reduce Motor/Tool life

Disables Dynamic brake during speed changes (Default)

unit must be powered off and on again for the DIP switch changes to be

Chapter 4: System Setup and Wiring (Rev. 2.1)

controllers for organi-

behind the access panel

DIP switch positions 1 ~ 3 are used for setting the special configuration features as defined in the

again for the DIP switch changes to be