Special d-no explanation – FEC FUSIONE-HS-2 User Manual

Page 136

Advertising
background image

Chapter 7: System Operations

Page 7-12

Special D-No Explanation

2)

Torque Unit [WORK]-00, [D-No]-00

00: Nm

02:Kgcm

04:In.Lb.

01: Kgm

03:Ft. Lb.

3)

ROM Version [WORK]-00, [D-No]-01

Displays Controller ROM Version (Not adjustable)

4)

Amplifier Version [WORK]-00, [D-No]-02

Displays Servo Version (Not adjustable)

5)

Fastening Function Version [WORK]-00, [D-No]-03.

The Fastening Function Version is entered into [WORK]-

00

, [D-No]-

03

.

Enter the Set no. which corresponds to the Function Version desired from the table below.

Alternate Fastening Function mode selection

An alternate function mode exists which allows setting of additional functions for the fusion controller.

The function version that is set in the controller will be displayed when viewing (Work 00, D-No-03).

The last two digits of the function version correspond to the two digits to the right of “18” in the table

below.

(Ex.- Display “1.03” corresponds to set-up of 1803)

To make a change (when the function version is being displayed D-No 03):

1. Depress [SET] and [MODE] buttons at the same time (PROGRAM mode)

2. Depress [MODE] button (Display should show Work 00 D-No – 03)

3. Depress [SET] button

4. The cursor will blink on the leftmost digit

5. Use the

[

↓↓↓↓]

and

[

↑↑↑↑]

buttons to enter “18xx” whereas the xx is the desired setting. (18 must always be

entered as the leftmost digits)

6. Depress the [SET] button to enter the change into memory

7. “CHNG – NO” will appear in the display, use the

[

↓↓↓↓]

and

[

↑↑↑↑]

buttons to change NO to YES in the display

8. Depress [SET] to confirm and enter the change to memory

9. Depress [SET] and [MODE] buttons at the same time (return to RUN mode)

10. System MUST be re-booted in order to change the function mode.

Shown below are the available options for setting of this Data No.;

Set No.

AFC

S/W

Comm. Speed Tool Type Work Select Method

1800

– Comm. Speed 38400bps : T-type, P-type or Tubenut : Work Select from Terminal TB1

1801

– Comm. Speed 38400bps : T-type, P-type or Tubenut : Work Select from Front Panel

1802

– Comm. Speed 38400bps : Angle Head type : Work Select from Terminal TB1

1803*

– Comm. Speed 38400bps : Angle Head type : Work Select from Front Panel

1810

– Comm. Speed 9600bps : T-type, P-type or Tubenut : Work Select from Terminal TB1

1811

– Comm. Speed 9600bps : T-type, P-type or Tubenut : Work Select from Front Panel

1812

– Comm. Speed 9600bps : Angle Head type : Work Select from Terminal TB1

1813

– Comm. Speed 9600bps : Angle Head type : Work Select from Front Panel

*

Denotes Default setting

Note: Adding (4) to any Set No. above, sets the Fastening function in “

DDK

Mode

”- Changing the RS232 data output protocol

as listed in [4.8.5 Rear Panel RS232 Alternate Communication Protocol].

The effect of the Work Select Method;

*Select from Terminal TB1: (Note: This MUST be configured when using a Fieldbus interface)

o

Work Select must take place from the TB1 Terminal located on the controller backpanel

o

Batch OK reset input MUST be applied for clearing cycle count

**Select from Front Panel :

o

Work Select can take place from the Controller front “WORK” button

o

Batch OK reset input can be applied for clearing cycle count or cleared automatically at

the next START (upon Accept)

Advertising