2final torque monitoring – FEC FUSIONE-HS-2 User Manual

Page 110

Advertising
background image

Chapter 6: Fastening Instructions

Page 6-14

6.2.2Final Torque Monitoring

Torque Monitoring is a continuous process whenever the system is operating. Final Torque monitor-

ing uses the torque value detected at the completion of fastening.

In Torque Control method, the Final Torque value and Peak Torque values will be identical except

in cases where Torque Recovery (Section 6.5) is enabled. In Torque Control method, the Final Tor-

que High and Low Torque limits are only selectable when Torque Recovery is enabled, and are typi-

cally set based upon the engineering specification for that specific fastener.

TORQUE CONTROL – TORQUE RECOVERY ENABLED

REJECT TYPE

CAUSES

FINAL TORQUE HIGH LIMIT

Excessive chatter of the torque signal due to slip stick friction.

Incorrect parameter set-up.

FINAL TORQUE LOW LIMIT

Reject condition caused by another monitor item reject.

FIG. 6-2-2a Final Torque Monitor – Torque Control W/ Torque Recovery

Snug Torque

Standard Torque

Threshold Torque

Speed Change Torque

1

st

Torque

Crossover Torque

Torque

Time Only

Peak Torque High Limit

Peak Torque Low Limit

1

st

Time

Final Time

Final Torque High Limit

Final Torque Low Limit

Torque Recovery Pulse Time

Advertising