Chapter 9: Troubleshooting

Page 9-14

9.10.6 Code 9-5 PARAMETER ERROR / TORQUE SETUP ERROR

One of the Torque presets is out of range

RECOVERY:

1. Verify that the Torque presets are in range for the tool size.

2. Check that the torque presets are not <0> or setup as specified in 6.1.1.

9.10.7 Code 9-6

PARAMETER ERROR / ANGLE SETUP ERROR

One of the Angle presets is out of range

RECOVERY:

1. Verify that the Angle presets are in range for the tool size.

2. Check that the Angle presets are not <0> or setup as specified in 6.1.2.

9.10.8 Code 9-7

PARAMETER ERROR / REVERSE TORQUE OVER.

The Reverse torque is more than 1.5 times the Full Scale Torque.

RECOVERY:

1. Verify that the preset value is correct.

2. If the value is correct, check the application. The size of the tool is not adequate for this

application or the fastener being reversed may be over-torqued.