Chapter 4: System Setup and Wiring

Page 4-26

4.9 T/A MON. DB9 Connector - External Torque/Angle/Current/Speed Output

This auxiliary connector is used to output Torque, Angle, Current & Speed signals to external

equipment for monitoring purposes (X-Y Plotter, etc). The signals output from this connector

are the same signals that the system receives during the fastening process. This connector

is not required for the system to operate.

No

Signal

In/Out

Description

1 None

2 None

3 Angle Pulse

Out

Angle Pulse Monitor TTL

4 Angle CW/CCW

Out

CW/CCW Monitor TTL

5 GND

Out

Ground

6 None

7 Current Monitor

Out

-10V

“

+10V 10V=(HFC-EC-16 16A )

8 Speed Voltage

Monitor

Out

-10V

“

+10V 10V=Max Speed

9 Torque Monitor

Out

Max Torque=2.5V

Torque voltage (Analog voltage)

Monitor voltage represents zero torque to full-scale torque by an electric

potential difference of 2.5V.

Zero Level voltage is voltage measured with the nutrunner stopped with no load.

Angle pulse (TTL signal 0V or 5V)

Angle pulse is output at 1 pulse per degree.

It differs slightly from the actual angle of rotation displayed from the controller.

Normal/reverse revolution pulse (TTL signal 0V or 5V)

A 5v (High) signal is output during CW revolution, and 0V (Low) signal is output during CCW

revolution.

Angle and direction are output as shown below;

CW/CCW

PULSES

ANGLE

ROTATION

TOOL

STOP

CW

CCW

Advertising