FEC FUSIONE-HS-2 User Manual

Page 170

Advertising
background image

Chapter 9: Troubleshooting

Page 9-2

9.1 Abnormal Conditions.

When an abnormal condition is detected by the system, the affected spindle stops, and lights

“Abn” in the [DATA] display. For ease of troubleshooting the nature of the abnormal, the sys-

tem provides an abnormal code in the [PARM] display and an abnormal sub-code in the

[COUNT/D-NO] display.

Note: ABNORMALS are not to be confused with fastening REJECTS. Abnormal’s signify a

failure of a system process or self check during the fastening cycle.

Abnormal code display

.

When an Abnormal condition occurs, the display mode will automatically change to the

STATUS mode. (If the display is not in the STATUS mode, depress the MODE button until a

blinking “A” appears in the [WORK] display area) A code number appears at the right side of

the blinking character. This code refers to some specific type of failure detailed in the tables

shown in the following sections.

Abnormal Sub-code display

.

The number shown at the most right position in the [COUNT/D-NO] display area is a sub-

code that can be used in conjunction with the Abnormal failure code to further narrow down

the cause of the fault. See the following sections.

Example of Abnormal Code 9 Sub-Code 0

Abnormal Code Table

ABNORMAL

CODE

DESCRIPTION

1

Torque Transducer Error.

2

Over Torque Error.

3

Tool EEPROM error.

4

System Memory Error.

5

Servo Amplifier Reply Error.

6

Servo Type Mismatch Error.

7

NOT USED

8

Servo Amplifier Error.

9

Parameter Error.

Abnormal sub-codes and specific actions for troubleshooting are detailed in the following

section.

WARNING:DO NOT CONNECT OR DISCONNECT CABLES OR OTHER SYSTEM

COMPONENTS WITH POWER APPLIED.

Advertising