Data No.83 CW Motor Resume Time (Pistol Pulse Function)
[Deg]
Setting Range: 0 – 1000
Used to set the motor resume time in the CW direction.
Data No.80 CCW Stop Angle (Pistol Pulse Function)
[Deg]
Setting Range: 0 – 360
Used to set the swing stop angle in the CW direction. This is the angle the pistol will swing up to be-
fore shutting off. Setting “180” disables function.
Data No.81 CCW Swing Pause Angle (Pistol Pulse Function)
[Deg]
Setting Range: 0 – 360
Used to set the swing Pause angle in the CW direction.
Data No.82 CCW Swing Stop Servo Lock Time (Pistol Pulse Function)
[Deg]
Setting Range: 0 – 1000
Used to set the swing stop servo lock time in the CW direction.
Data No.83 CCW Motor Resume Time (Pistol Pulse Function)
[Deg]
Setting Range: 0 – 1000
Used to set the motor resume time in the CW direction.