FEC FUSIONE-HS-2 User Manual

Page 147

Advertising
background image

FUSION Operations Manual Chapter 7: System Operations (Rev.2)

Page 7-23

Data No.83 CW Motor Resume Time (Pistol Pulse Function)

[Deg]

Setting Range: 0 – 1000

Used to set the motor resume time in the CW direction.

Data No.80 CCW Stop Angle (Pistol Pulse Function)

[Deg]

Setting Range: 0 – 360

Used to set the swing stop angle in the CW direction. This is the angle the pistol will swing up to be-

fore shutting off. Setting “180” disables function.

Data No.81 CCW Swing Pause Angle (Pistol Pulse Function)

[Deg]

Setting Range: 0 – 360

Used to set the swing Pause angle in the CW direction.

Data No.82 CCW Swing Stop Servo Lock Time (Pistol Pulse Function)

[Deg]

Setting Range: 0 – 1000

Used to set the swing stop servo lock time in the CW direction.

Data No.83 CCW Motor Resume Time (Pistol Pulse Function)

[Deg]

Setting Range: 0 – 1000

Used to set the motor resume time in the CW direction.