FUSION Operations Manual Chapter 7: System Operations (Rev.2)

Page 7-19

Data No.1B Breakaway Torque Limit

[Nm, Kgm...]

Setting range: 0 ~ [10: Calibration torque] × 1.1

When this torque is exceeded during Reverse 2 or 3 operations, an Abnormal will be

generated that will stop the operation.

Data No.1C Final Low Torque

[Nm, Kgm...]

Data No.1D Final High Torque

[Nm, Kgm...]

Setting range: 0 ~ [10: Calibration torque] × 1.1

For [Angle Method], sets the High and Low limits for Torque at the point that the final Fastening Angle

is achieved.

For [Torque Method], during Torque Recovery, sets the High and Low limits for Torque at the

point that the final Fastening is completed.

Data No.1E 2ND Rate Start Torque

[Nm, Kgm...]

Setting range: 0 ~ [10: Cal torque] × 1.0

Start point for 2

nd

Torque rate monitoring [Crossover is the end]

Data No.26 2ND Rate Start Angle

[deg]

(NOT USED as standard function)

Setting range: 0 ~ 9999 degrees

Start point for 2

nd

Torque rate monitoring [CROS Torque/Angle is the end]

Torque

Angle

26 2ND

24 CROS

32 Rate 2 Low Limit

33 Rate 2 High Limit

Angle

18 CROS

1E 2ND

32 Rate 2 Low Limit

33 Rate 2 High Limit

Torque

If 2nd Torque Rate monitoring is not required, [1E:2

nd

Rate Start Torque] should be

set the same or higher than [10: Calibration Torque]