Chapter 4: System Setup and Wiring (Rev. 2.1)

Page 4-25

4.8.5 Rear Panel RS232 Alternate Communication Protocol

An alternate communication protocol is available upon set-up in a different “Fastening Func-

tion Mode” (See 7.2.5 Fastening Function Version [Work]-00, [D-No]-03) If the system is set-

up in a “DDK” mode, this protocol becomes the Standard Communication Protocol.

This alternate protocol has 79 bytes of data per fastening.

Byte

1

2

3

4

5

6

7

8

9

10

11

12

13

14

Desc.

Cycle Count

Spindle

Number

Work

Number

ASCII

Hex

30H 30H 30H 31H 20H 20H 30H 31H 20H 20H 20H 31H 20H 20H

Data

0

0

0

1

0

1

1

Byte

15

16

17

18

19

20

21

22

23

24

25

26

27

28

Desc.

Peak Torque

Judge

Final Angle

Judge

ASCII

Hex

31H 32H 2EH 33H 34H 4CH 20H 20H 20H 20H 35H 30H 48H 20H

Data

1

2

.

3

4

L

5

0

H

Byte

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

Desc.

Final Torque

Judge

1st Rate

Judge

ASCII

Hex

31H 32H 2EH 33H 34H 20H 20H 20H 30H 2EH 31H 32H 33H 20H 20H 20H

Data

1

2

.

3

4

0

.

1

2

3

Byte

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

Desc.

2nd Rate

Judge

3rd Rate

Judge

ASCII

Hex

30H 2EH 31H 32H 33H 20H 20H 20H 30H 2EH 31H 32H 33H 20H 20H 20H

Data

0

.

1

2

3

0

.

1

2

3

Byte

61

62

63

64

65

66

67

68

69

70

71

72

73

74

75 76

77

78 79

Desc.

1st Time

Judge

2nd Time

Judge

Final

Judge

CR LF

ASCII

Hex

20H 31H 30H 2EH 30H 20H 20H 20H 20H 20H 32H 2EH 30H 20H 20H 20H 58H 0DH 0AH

Data

1

0

.

0

2

.

0

X

Final Judgment: “X” Reject = 58H, “O” Accept = 4FH, “A” Abnormal = 41H, “S” Stop=53H, “B” Bypass=42H