FEC FUSION Operations Manual

Chapter 4: System Setup and Wiring (Rev. 2.1)

Page 4-47

I/O Signal Map

(Continued)

From PLC to Fusion – (4 Bytes – 32 Bits)

Octal Bit Description

Comment

O:00

0

0

1

1

2

2

3

3

4

4

5

5

6

6

Abort Job

Reserved for Future Use

7

7

Reset

O:00

10

8

11

9

12

10

13

11

14

12

Work Select/Job 0

Job Function is Future

15

13

Work Select/Job 1

Job Function is Future

16

14

Work Select/Job 2

Job Function is Future

17

15

Work Select/Job 3

Job Function is Future

O:01

0

0

Stop

1

1

Reset

2

2

Reverse

3

3

Start

4

4

Bypass

5

5

Disable Self-check

6

6

7

7

O:01

10

8

11

9

12

10

13

11

14

12

In 12

Terminal Input 12 not assigned

15

13

In 13

Terminal Input 13 not assigned

16

14

In 14

Terminal Input 14 not assigned

17

15

In 15

Terminal Input 15 not assigned

Firmware Set-up

Two items are configurable in the set-up of the Fusion controller for the Allen Bradley Remote

I/O interface. Both the I/O Rack Starting Quarter and the Last Rack setting is set-up in the

system parameter settings.

I/O Starting Quarter

Sets the Starting Quarter for the rack address

WORK [00] Data No. [28]

“0”: 1

st

Quarter

“1”: 2

nd

Quarter

“2”: 3

rd

Quarter

“3”: 4

th

Quarter

Last Rack

Sets the Fusion system as the last rack or not on the Remote I/O link

WORK [00] Data No. [29

]

“0”: Not Last Rack

“1”: Last Rack