FEC FUSIONE-HS-2 User Manual

Page 140

Advertising
background image

Chapter 7: System Operations

Page 7-16

Data No.14 Speed Change Torque

[Nm, Kgm...]

Setting range: 0 ~ [10: Calibration torque] × 1.0

Set the torque value that switches slow down speed to torque speed.

Data No.15 1ST Torque

[Nm, Kgm...] Setting range: 0 ~ [10: Calibration torque] × 1.0

Data No.23 1ST Angle

[deg]

Setting range: 0 ~ 9999

1

ST

stop / synchronization point for multiple step fastening operations.

End point for 1

st

torque rate calculation. [17: Threshold Torque is beginning]

Shift point for changing to Torque Speed [53: Torque Speed]

End of 1

st

Time and beginning of Final Time

Even if Freerun Revolutions are not achieved, the speed will change to

Slow Down Speed when Speed Change Torque is detected.

SPEED

60 Freerun Revolutions

51 Freerun

Speed

40 Initial Time

14 Speed Change Torque

52 Slowdown Speed

53 Torque Speed

54 Reverse Speed

50 Initial Speed

63 Reverse Revolutions

Fastening

Advertising