FEC FUSION Operations Manual Chapter 2: Specifications (Rev. 2.1)

Page 2-3

2.2

Duty Cycle Calculation

Duty Cycle is rated as a percentage of the time the motor is running to the time the motor is

idle. This is an important factor in determining overload protection for Servo Amplifiers and

motors as it directly relates to the amount of power or heat dissipation of the motor / servo

package. The rated duty cycle for the FUSION System is calculated as follows:

Tool Rotation Time

X 100 = Duty Cycle Percentage (%)

Total Cycle Time (Tool Rotation + Tool Waiting)

Example:

Tool Rotation Time = 3 Seconds x 100 = 25% Duty Cycle Percentage

Total Cycle Time =

12 Seconds

Duty cycle ratings vary between tools. As a general rule, however, it should not exceed 50%.

IF duty cycles remain above 60% for extended periods, a Servo Amplifier Error / Overload will

result (See abnormal CODE 8 -10)

.

Protection for high duty cycle is a standard feature of the

Servo Amplifier to prevent servo or motor damage.