FEC FUSIONE-HS-2 User Manual

Page 62

Advertising
background image

Chapter 4: System Setup and Wiring

Page 4-24

4.8.4 Rear Panel RS232 Abbreviated Communication Protocol

The RS232C output format can be switched between the standard format (preceding page)

and the abbreviated format shown below. This function is available in firmware versions 2.22

or later. The table below describes the data set-up for enabling and configuring the abbre-

viated output format.

Work #

Data #

Item

Setting

00

40

Format selection

0: Standard (214 bytes) Data # 41 ~ 49 Disabled

1:Abbreviated (32bytes) Data # 41 ~ 49 Enabled

00

41

End data selection

0: 0Dh (CR) 1: 0Ah (LF) 3: 0Dh+0Ah (CR & LF)

00

42

Comm. Speed

1: 9600 BPS 2: 19200BPS 3: 38400BPS

00

43

Data bit

0: 7Bit 1: 8 Bit

00

44

Stop bit

0: 1 Bit 1: 2 Bit

00

45

Parity

0: None 1: Even 2: Odd

00

46

Torque data

0: No data 1:Enable data

00

47

Angle data

0: No data 1:Enable data

00

48

Cycle Time data

0: No data 1:Enable data

00

49

Judgment

0: No data 1:Enable data

Example of abbreviated format:

Byte

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

Desc.

Spindle # Work

Cycle Count

Peak Torque

Final Angle

ASCII

Hex

23H 31H 31H 30H 31H 32H 31H 32H 2EH 33H 34H 31H 31H 32H 2EH 33H

Data

#

1

1

0

1

2

1

2

.

3

4

1

1

2

.

3

Byte

17

18

19

20

21

22

23

24

25

26

27

28

29

30

Desc.

Not Used

Cycle Time

Judge

ASCII

Hex

30H 30H 30H 30H 30H 30H 30H 30H 30H 31H 32H 2EH 33H 40H

Data

0

0

0

0

0

0

0

0

0

1

2

.

3

@

Byte

31

31

31

32

Desc.

ASCII

Hex

0DH OR 0AH OR 0DH 0AH

Data

CR

LF

CR

LF

Definition of “Judge” (Byte 30):

@ = Accept G = Stop

E = Low Time Reject F = Time Reject

P = Bypass

K = Angle High Reject J = Angle Low Reject

I = Torque High Reject H = Torque Low Reject

A = Abnormal X = Other Reject

Advertising