FEC FUSIONE-HS-2 User Manual

Page 113

Advertising
background image

FEC Fusion Operations Manual Chapter 6: Fastening Instructions (Rev. 2)

Page 6-17

For Torque Control operations, the High and Low Angle limits are either set by the engineering speci-

fication for that specific fastener, or by determining the acceptable limits from a study of known good

and bad assemblies. The High Angle limit will stop the fastening process for Torque Control opera-

tions if it is reached before attaining the desired torque.

TORQUE CONTROL

REJECT TYPE

CAUSES

HIGH ANGLE LIMIT

Increased joint compression.

Reduced joint friction.

High initial prevailing torque.

Incorrect parameter set-up.

LOW ANGLE LIMIT

Reduced joint compression.

Increased joint friction.

Reject condition caused by another monitor item reject.

FIG. 6-2-3b Angle Monitoring – Torque Control

Snug Torque

1

st

Time

Final Time

Standard Torque

Threshold Torque

Speed Change Torque

1

st

Torque

Crossover Torque

Torque

Angle/Time

Peak Torque High Limit

Peak Torque Low Limit

Angle High Limit

Angle Low Limit

Advertising